This device performs hematology analyses based on the hydrodynamically focused impedance measurement, the flow cytometry method using a semiconductor laser and the SLS-hemoglobin method. Cytometry is used to analyze physiological and chemical characteristics of cells and other biological particles.

Flow cytometry is a method used to analyze those cells and particles as they pass through extremely small flow cells. Follow specimen handling as outlined by laboratory safety policy. Wear safety glasses if there is a risk of splashing. By hemolyzing red blood cells with Lysercell WDF and dying the white blood cell component with Fluorocell WDF, the counts and percentages of neutrophils, lymphocytes, monocytes, eosinophils and basophils are analyzed.

Lysercell WDF does not have ingredients with those characteristics. Fluorocell WDF: Used to stain the leukocytes in diluted and lysed blood samples for determination of differential count in blood. Refer to the SDS. However, no current tests can assure the absence of these pathogens.

The process for checking the accuracy and precision of an analyzer at regular timed intervals is known as calibration verification. Historically, a calibrator has been used on a semi-annual basis as a "check" of daily QC procedures. Since our instrument uses a BeyondCare Quality Monitor application, calibration is verified each time QC is analyzed and the results fall within algorithm specification guidelins developed for the BeyondCare Quality Monitor program.

This means that calibration verification will be verified every 24 hours. In the "Intended Use" section of the control package inserts, it states that the controls are intended for quality control and calibration verification.

If physical recalibration is necessay, Sysmex technicians will come to the lab and perform the calibration on site. BCQM supplies the laboratory with a laptop which can be accessed to provide calibration history at any time. QC and Calibration Verification will be checked by the Supervisor weekly. For a calendar view of whether the QC passed or failed, access the Summary report in the BCQM lap top from the dashboard icon which will also display the background status.

Changing your perspective – XN technology for every lab

Along the bottom of the screen, the codes appearing in the chart boxes will be explained. The BeyondCare Quality Monitor program establishes the target and limit values for the new QC lot as soon as the first vial of each level gets analyzed. The BeyondCare Quality Monitor application stores the last 2. All QC data older than 2.

Once these reports have been reviewed through the BeyondCare Quality Monitor application, they can be accessed by going to Activity - Reviewed Documents. Reports are archived for 2. Reports that are older than 2. Check for cold agglutinin by placing in 37C incubator for intervals of 15 min; check for lipemia, hemolysis.We are using cookies on this website. We assume your consent, as you are making use of this website. A cookie is a simple small file sent with the pages of this website and stored by your browser on the hard disk of your computer.

The stored information can be resent to our servers the next time you visit the website. Hide this message. Sysmex Middle East. Who is Sysmex? About us. The Sysmex Way. Silent Design. Reagent production. Investor information.

sysmex xn 330

EMEA management. Regulatory and Legal Affairs. The Sysmex System. Quality and ISO. Compliance code. News and Events. Social Media. Your career at Sysmex.

Work areas. Job listing. Contact us. Digital imaging.

sysmex xn 330

XN-L Series. Reagents RPU unit. Veterinary solutions. Point of Care. Solutions for optimised cancer mangement. Sentinel lymph node detection Sentimag. Sentinel lymph node analysis OSNA. Flow Cytometry.We are using cookies on this website. We assume your consent, as you are making use of this website. A cookie is a simple small file sent with the pages of this website and stored by your browser on the hard disk of your computer. The stored information can be resent to our servers the next time you visit the website.

Hide this message. Of course we are glad to provide you with a selection of literature, but reference ranges from different studies are only conditionally transferable, depending on age, gender, ethnicity, etc.

For this reason, the individuals who served as the basis for the selected reference range should be as similar as possible to the patient population to whom the reference range is to be applied.

Currently, there are several scientific publications that provide information about the reference ranges for Sysmex analysers see table below. These studies were performed mainly using X-Class haematology analysers and it can be seen that the reference ranges differ according to the populations involved. Therefore, published reference ranges from older analysers may be used on newer analysers, but only after validation. Since — as explained above — there are differences between haematological reference ranges from different populations, the information in the table may facilitate the selection of an appropriate reference range as an initial point for validation.

Adopting a published reference range without validation is not permissible and can even be dangerous for patients. Its suitability as a reference must be examined in every case. To do this, the IFCC suggests the following procedure:. If not more than 2 of the 20 samples are outside this range, it can be used.

If 3 - 4 samples are outside the reference range, a further 20 new samples must be taken. If not more than 2 of these 20 samples are outside the range, it can be used. If in the initial verification, 5 or more samples, or more than 2 of a repeated set of samples, are outside the published range, it is not suitable for use as a reference for local patients. The alternative is then a new survey or validation of another, different reference range. Sysmex Middle East.

Who is Sysmex? About us. The Sysmex Way. Silent Design. Reagent production. Investor information. EMEA management. Regulatory and Legal Affairs. The Sysmex System. Quality and ISO. Compliance code. News and Events. Social Media.

Your career at Sysmex. Work areas. Job listing. Contact us.Forgot password? Why Register? Sysmex introduced its first blood counter in Inwe helped advance the industry with the first automated hematology system that combined cell analysis with slide-making staining.

Using a diode laser bench, fluorescent flow cytometry provides the sensitivity needed for measuring and differentiating cell types in whole blood and body fluid samples.

This simplified system of analyzer operation and user interface enables laboratories of any size to implement advanced clinical and operational capabilities. Concentrated reagents and compact packaging simplify consumable inventory management, saving time and storage space.

These automaton systems offer the option of our new, 5th generation slidemaker-stainer, the SP, as well as other analytical modules. The XN offers an additional analysis channel, the white precursor cell WPC channel, which provides improved differentiation of abnormal WBC populations, to add further efficiency to your laboratory. XN-L provides enhanced clinical value in a small compact footprint.

Hematology Analyzer XN-330 100,000 Samples

Choose between the three XN-L models that best manage your workflow need. With common reagents and operating software, XN-L can help to promote standardized testing from the central laboratory, to satellite labs, to affiliated clinics and physician office labs. Smaller reagent sizes and concentrated reagents simplify consumable inventory management.

Using a novel combination of fluorescence technology, highly specific reagents, and an intelligent counting algorithm, GloCyte can handle all of the cerebrospinal fluid CSF specimens that enter your laboratory. It provides accurate cell counts at clinically relevant low levels and reduces valuable time spent counting those more difficult specimens. Improve analyzer availability and productivity by reducing the non-value-added work of reagent changes, improve productivity with patient results that are reported faster, and decrease the risk of injury associated with lifting and moving heavy, bulk reagent.

Simple menus with proven direct current detection technology minimize training requirements for your staff. Alifax Erythrocyte Sedimentation Rate ESR Analyzer Series : Efficiency is critical as physicians demand fast turnaround, which is vital to maintain a high level of patient care. If you need to do more with less - we have a solution. Walk away from ESR.

Automated results in 20 seconds. Order Tracking.We are using cookies on this website. We assume your consent, as you are making use of this website. A cookie is a simple small file sent with the pages of this website and stored by your browser on the hard disk of your computer.

The stored information can be resent to our servers the next time you visit the website. Hide this message. It offers effective and reliable internal and external quality control of the XN-Series haematology system.

The careful packaging protects it from evaporation and damage and ensures it is stable for longer. It includes white blood cells for the differential, reticulocyte fractions and nucleated red blood cells. This leads to a distinctive display of all the relevant cell populations in the appropriate scattergram.

It lets you control all measurement channels. They are then compared to results of other systems of the same type. Just a few minutes after performing the measurement, a performance comparison to international peer group data is available in addition to the familiar assay value comparison of the internal QC. Individual results can be viewed on the SNCS website after a password-protected log-in specifying your details. It provides a daily external QC scheme without the need for any additional control material.

The volume is 3. Sverige SV. Sysmex Sverige. Who is Sysmex? About us. The Sysmex Way.

Qualität im Kleinformat - Hämatologie für jedes Labor

Reagent production. Regulatory and Legal Affairs. The Sysmex System. Quality and ISO. Compliance code. News and Events. News listings. Event calendar. Contact us.

sysmex xn 330

Veterinary solutions. XN-L Series. Molecular diagnostics. Breast cancer.

SYSMAX XN-450

Colorectal cancer.Forgot password? Why Register? The introduction of the XN-Series hematology analyzers has helped Sysmex become the market leader in CBC testing performed by large and mid-volume labs. Now XN-L brings the same clinical and operational values to lower volume labs.

Reference Ranges – and what Sysmex can offer

Sysmex XN-L automated hematology analyzers offer expanded clinical value. If you have any questions or inquiries, please speak with your Sysmex representative or email hemeproductmktg sysmex. Customers located in Canada: Product availability may be different from the U. Please call Sales at for more information.

Order Tracking. Email Us. Register or Log in. Shaping the Future of the Clinical Laboratory. Lighting the way with diagnostics. Products and Services. Training and Education. About Us. Contact Us. Sysmex Landing Page Image1. Sysmex Landing Page Image2. Sysmex Landing Page Content. Standardization XN-L can provide standardized testing from core lab to satellite labs, and affiliated clinics and POLs.

Click Here to View Video. Click Here to Review Product Specifications. Quality and Compliance. Privacy Policy.We are using cookies on this website. We assume your consent, as you are making use of this website. A cookie is a simple small file sent with the pages of this website and stored by your browser on the hard disk of your computer.

The stored information can be resent to our servers the next time you visit the website. Hide this message. Please select your country. This will keep you up to date with your country-specific information. Experience the value of larger devices at an excellent price—quality relation: XN-L Pure is a budget-friendly, stand-alone haematology analyser that maintains the quality of higher-end solutions, including their strong reliability of results.

Your Sysmex representative can tell you more. Europe EN. Sysmex Europe. Who is Sysmex? About Us. Investor Information. Reagent production. The Sysmex System. News and Events. News listings. Event calendar. Press releases. EMEA headquarters. Contact us. Molecular diagnostics OSNA. Digital imaging.